- Fourth hose to enable connection to hi-/lo-sides, refrigerant tank and recovery unit or vacuum pump for diagnostics, evacuation and charging without switching hoses
- 3/8″ Vacuum port for use with larger hose to cut evacuation time by up to 33% (all other fittings are 1/4″)
- Large, easy-to-read 3-1/8″ (90 mm) steel case red and blue, 1% accuracy (Class 1) gauges
- Front access for easy field recalibration
- Double “O” ring piston for reliability and long service life
- Exclusive 100 mesh filter in-line on all flare fittings helps keep out particulate material and extend the life of the seats
- Contoured easy-grip handles for positive control; color-coded for ready identification
- Sight glass to easily view refrigerant movement and condition during charging and recovery
- Optional protective gauge boots available
- Heavy duty hook won’t pull out
- Also available with 3-1/2″ (80 mm) red and blue liquid-filled gauges
- Manifold and hose holder fittings 1/4″-3/8″-1/4″-1/4″ unless otherwise identified
- Made in the USA
Quick Select Tool Degree Refrigerant UPC# Description °F and °C (Fahrenheit and Celsius) 49913 49914 With 60″ PLUS II™ RYB and 3/8″ x 45°, R/B gauges, kPa/psi, R32/R410A – °F and °C 49914 Manifold only with 5/16″-3/8″-5/15″-5/16″ anchor and service fittings, R/B gauges, kPa/psi, R32/R410A – °F and °C 49915 Manifold only with 5/16″-3/8″-1/4″-5/16″ anchor fittings and 1/4″-3/8″-1/4″-1/4″ service fittings, R/B gauges, kPa/psi, R32/R410A, °F and °C 49922 Manifold only, liquid gauges, bar/psi, R22 – °F and °C 49925 With 60″ PLUS II™ RYB and 3/8″ x 45°, liquid gauges, bar/psi, R22 – °F and °C 49960 With 60″ PLUS II™ compact ball valve RYB and 3/8″ x 40°, R/B gauges, bar/psi, R32/R410A – °F and °C 49962 Manifold only, R/B gauges, bar/psi, R32/R410A – °F and °C 49964 Manifold only with 5/16-3/8-5/16-5/16″ fittings, R/B gauges, bar/psi, R32/410A – °F and °C 49965 With 60″ PLUS II™ RYB and 3/8″ x 45°, R/B gauges, bar/psi, R32/R410A – °F and °C 49966 Manifold only with 1/4″ fittings, R/B gauges, bar/psi, R32/410A – °F and °C 49971 Heat pump manifold only, 1/4×5/16×1/4 hose holder fittings, R410A – °F and °C 49982 Manifold only, liquid gauges, bar/psi, R410A – °F and °C °F (Fahrenheit) 49907 Manifold only, R/B gauges, bar/psi, R448A/449A/452A – °F 49973 Manifold only, liquid gauges, psi, R22/410A – °F 49977 With 60″ PLUS II™ RYB and 3/8″ x 45°, liquid gauges, R22/410A – °F 49963 Manifold only, R/B gauges, psi, R22/404A/410A – °F 49967 With 60″ PLUS II™ RYB and 3/8″ x 45°, R/B gauges, psi, R22/404A/410A – °F 49968 With 60″PLUS II™ compact ball valve RYB and 3/8″ x 45°, R/B gauges, psi, R22/404A/410A – °F 49283* Manifold only, R/B gauges, psi, R22/404A/410A – °F 49983 Manifold only, R/B gauges, psi, R22/134a/404A – °F 49987 With 60″ PLUS II™ RYB and 3/8″ x 45°, R/B gauges, psi, R22/134a/404A – °F 49993 Manifold only, liquid gauges, R22/134a/404A – °F 49997 With 60″ PLUS II™ RYB and 3/8″ x 45°, liquid gauges, psi, R22/134a/404A – °F 49932 Manifold only, R/B gauges, psi, R134a/404A/407C – °F 49935 With 60″ PLUS II™ RYB and 3/8″ x 45°, R/B gauges, psi, R134a/404A/407C – °F 49952 Manifold only, liquid gauges, psi, R134a/404A/407C – °F 49955 With 60″ PLUS II™ RYB and 3/8″ x 45°, liquid gauges, psi, R134a/404A/407C – °F 49900 With 72″ PLUS II™ RYB and 3/8″ x 45°, R/B gauges, psi, R417A/422A/422D – °F °C (Celsius) 49901 Manifold only, R/B gauges, bar/psi, R448A/449A/452A – °C 49916 Manifold only, R/B gauges, bar/psi, R12/22/502 – °C 49933 Manifold only, R/B gauges, bar/psi, R22/134a/404A – °C 49912 Manifold only, R/B gauges, kPa/psi, R22/134a/404A – °C 49911 49912 with 60″ PLUS II™ RYB and 3/8″ x 45°, R/B gauges, kPa/psi, R22/134a/404A – °C 49931 Manifold only, R/B gauges, bar/psi, R134a/404A/407F – °C 49934 Manifold only, no sight glass, R/B gauges, bar/psi, R134a/404A/407F – °C 49936 Manifold only, R/B gauges, bar/MPa, R134a/404A/407C – °C 49956 Manifold only, R/B gauges, bar/psi, R134a/404A/407C – °C 49972 No sight glass; 800 psi both gauges; bar/psi *49283 comes standard with certified gauges. Rebuild Kit 41082 TITAN 4-Valve Rebuild Kit
Cause injury or property damage. Refer to this manual. For assistance or additional information consult a qualified installer, service agency or the gas supplier. This system uses R-410A Refrigerant which operates at higher pressures than R-22. No other refrigerant may be used in this system. Gauge sets, hoses, refrigerant. Shinco Service Manual - 1 - SERVICE MANUAL Model. Refrigerant R410A(pre-charged) R410A(pre-charged) R410A(pre-charged) R410A(pre-charged). 20 72.813 78.388 84. View & download of more than 135 Tenma PDF user manuals, service manuals, operating guides. Power Supply, Multimeter user manuals, operating guides & specifications.
*SX14 R-410A Remote
Condensing Unit
ASX140181BA
ASX140181CA
ASX140241BA
ASX140241CA
ASX140301BA
ASX140301CA
ASX140361BA
ASX140361CA
ASX140421CA
ASX140421DA
ASX140481BA
ASX140481CA
ASX140601BA
SSX140181BA
SSX140241BA
SSX140301BA
SSX140361BA
SSX140421CA
SSX140481BA
This manual is to be used by qualified technicians only. | This manual replaces RP-536D | |
© 2009-2010 Goodman Manufacturing Company, L.P. ◊ 5151 San Felipe, Suite 500 ◊ Houston, TX 77056 | ||
RP-536E | www.goodmanmfg.com www.amana-hac.com | November 2010 |
Important Information | |
Index | |
Functional Parts List ................................................................................................... | 3 |
Illustration and Parts ................................................................................................... | 4 - 11 |
Views shown are for parts illustrations only, not servicing procedures.
Revision E: Added model SSX140481BA.
Text Codes:
AR - As Required
NA - Not Available
NS - Not Shown
00000000 - See Note
QTY - Quantity | Example (QTY 3) (If Quantity not shown, Quantity = 1) | |
M - Model | Example (M1) (If M Code not shown, then part is used on all Models) | |
Expanded Model Nomenclature: | ||
Example | ||
M1 - Model#1 | ||
M2 - Model#2 | ||
M3 - Model#3 |
Goodman Manufacturing Company, L.P. is not responsible for personal injury or property damage resulting from improper service. Review all service information before beginning repairs.
Warranty service must be performed by an authorized technician, using authorized factory parts. If service is required after the warranty expires, Goodman Manufacturing Company, L.P. also recommends contacting an authorized technician and using authorized factory parts.
Goodman Manufacturing Company, L.P. reserves the right to discontinue, or change at any time, specifications or designs without notice or without incurring obligations.
For assistance within the U.S.A. contact:
Consumer Affairs Department Goodman Manufacturing Company, L.P. 7401 Security Way
Houston, Texas 77040 877-254-4729-Telephone 713-863-2382-Facsimile
For assistance outside the U.S.A. contact:
International Division
Goodman ManufCompany,cturingL.P.Company, L.P.
7401 Security Way Houston, Texas 77040 713-861-2500-Telephone 713-863-2382-Facsimile
Functional Parts
Part
No: Description:
0151R00002P 3/4' SERVICE VALVE OPEN LEFT (M1, M2, M3, M4, M5, M6, M7, M8, M14, M15, M16, M17)
0130M00011P LOW AMBIENT THERMOSTAT, SPDT (M1, M2, M3, M4, M5, M6, M7, M8, M9, M10, M11, M12, M13)
B12825171 | 3/8” SERVICE VALVE |
0151R00003P | 7/8' SERVICE VALVE OPEN LEFT (M9, M10, |
M11, M12, M13, M18, M19) | |
CAP050300440RSS | CAPACITOR 5/30/370V (M1, M2, M14) |
CAP050350440RSS | CAPACITOR 5/35/440V (M3, M4, M15) |
CAP050400440RT | CAPACITOR 5/40/440V (M5, M6, M16) |
CAP050450440RT | CAPACITOR 5/45/440V (M7, M8, M9, M10, |
M11, M12, M17, M18, M19) | |
CAP050700440RTS | CAPACITOR 5/70/440V (M13) |
543001001 | COMFORT ALERT MODULE (M2, M4, M6, M8, |
M10, M11, M12, M13) | |
543001000S | COMFORT ALERT MODULE (M1, M3, M5, M7, |
M9) | |
ZP20K5EPFV130 | COMPRESSOR 20000, 208/230/60/1 (M3, M4, |
M15) | |
ZP24K5EPFV130 | COMPRESSOR 24000, 208/230/60/1 (M5, M6, |
M16) | |
ZP29K5EPFV130 | COMPRESSOR 29000, 208/230/60/1 (M7, M8, |
M17) | |
ZP31K5EPFV830 | COMPRESSOR 31100, 208/230/60/1 (M9, |
M10, M18) | |
ZP38K5EPFV130 | COMPRESSOR 37500, 208/230/60/1 (M11, |
M12, M19) | |
ZP51K5EPFV830 | COMPRESSOR 51000, 208/230/60/1 (M13) |
ZP16K5EPFV130 | COMPRESSOR15500, 208/230/60/1 (M1, M2, |
M14) | |
0131M00019P | COND MOTOR 1/12 HP, 1 SP, 8 PL (M15) |
0131M00027 | COND MOTOR 1/12 HP, 2 SP, 8 PL (M3, M4) |
0131M00061S | COND MOTOR 1/4 HP, 1 SP, 8 PL (M19) |
0131M00015PS | COND MOTOR 1/4 HP, 2 SP, 8 PL (M11, M12, |
M13) | |
0131M00060S | COND MOTOR 1/6 HP, 1 SP, 8 PL (M14, M16, |
M17, M18) | |
0131M00017PS | COND MOTOR 1/6 HP, 2 SP, 8 PL (M1, M2, |
M5, M6, M7, M8, M9, M10) | |
CONT1P025024VS | CONTACTOR 25 AMP, 1P, 24V (M1, M2, M3, |
M4, M5, M6, M7, M8, M9, M10, M14, M15, M16, | |
M17, M18) |
0130M00082 | LOW PRESSURE SWITCH (M12, M19) |
0130R00001 | LOW PRESSURE SWITCH (M1, M2, M3, M4, |
M5, M6, M7, M8, M9, M10, M11, M13, M14, | |
M15, M16, M17, M18) |
SPECIAL PARTS
0161R00008P AMANA LOGO CAP (M1, M2, M3, M4, M5, M6, M7, M8, M9, M10, M11, M12, M13)
0161R00010P | AMANA NAMEPLATE (M1, M2, M3, M4, M5, |
M6, M7, M8, M9, M10, M11, M12, M13) | |
IO-258J | INSTRUCTION, INST |
0161R00009P | NAMEPLATE (M14, M15, M16, M17, M18, M19) |
Tenma 72 410a Manual
Expanded Model Nomenclature
M1 - ASX140181BA
M2 - ASX140181CA
M3 - ASX140241BA
M4 - ASX140241CA
M5 - ASX140301BA
M6 - ASX140301CA
M7 - ASX140361BA
M8 - ASX140361CA
Tenma 72 410a Manual
M9 - ASX140421CA
M10 - ASX140421DA
M11 - ASX140481BA
M12 - ASX140481CA
M13 - ASX140601BA
M14 - SSX140181BA
M15 - SSX140241BA
M16 - SSX140301BA
M17 - SSX140361BA
M18 - SSX140421CA
Tenma 72-410a Manual
M19 - SSX140481BA
CONT1P030024VS | CONTACTOR 30 AMP, 1P, 24V (M11, M12, |
M13, M19) | |
0150M00001P | FAN BLADE 20 INCH (M3, M4, M15) |
0150M00012S | FAN BLADE 20' CCW (M1, M2, M14) |
0150M00008S | FAN BLADE 22' TNT2203-25 (M7, M8, M9, |
M10, M17) | |
10625738S | FAN BLADE 26' ALUM CCW (M11, M12, M13, |
M19) | |
B1086764S | FAN BLADE TYPE 2 (M5, M6, M16, M18) |
20322603 | HIGH PRESSURE SWITCH |